BEGIN:VCALENDAR
PRODID:NingEventWidget-v1
VERSION:2.0
METHOD:PUBLISH
BEGIN:VTIMEZONE
TZID:America/New_York
X-LIC-LOCATION:America/New_York
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:19700308T020000
RRULE:FREQ=YEARLY;BYMONTH=3;BYDAY=2SU
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:19701101T020000
RRULE:FREQ=YEARLY;BYMONTH=11;BYDAY=1SU
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
UID:2140535:Event:56567
DTSTAMP:20260520T185037Z
SUMMARY:Implement Parametric Release in EO Sterilization - A Practical
  Approach
DESCRIPTION:This webinar will present a practical approach for impleme
 nting parametric release in EO sterilization. We will discuss the cycl
 e validation and other requirements for implementation of parametric r
 elease in EO sterilization as per EN/ISO 11135.\nWhy Should You Attend
 :\nEven though many companies are utilizing the advantage of parametri
 c released for theirEO sterilized products, there are some which stil
 l thinks is too complex or risky to be implemented. Latest EN/ISO 111
 35 and TIR 20 revisions clearly defines the validation requirements
  but since it does not provides guidance on how to establish the param
 eters many sterilization experts has doubts regarding this critical as
 pect.\nWe developed this training utilizing not only the ISO guidance
 's but the hands-on experience acquired while successfully establishi
 ng parametric release for severalmedical device manufacturing compani
 es.  Learn the use of this practical approach which will allow for a 
 simple, straight-forward implementation of parametric release which ha
 s been evaluated by the FDA and found in compliance in all of these co
 mpanies. We will discuss the validation and other requirements along w
 ith monitoring methods.\nAreas Covered in the Seminar:\n\nIntroduction
 .\nCycle Validation for parametric release.\nMicrobiology requirements
 .\nMethods A or B\n\n\nEquipment Requirements\nPre-conditioning\nSteri
 lization\nAeration\n\n\nProduct considerations\nPallet configuration\n
 Product density\n\n\nParameter Establishment for routine monitoring\nH
 umidity\nEO concentration\nProduct temperature\n\n\n\n\nRoutine EO cyc
 le monitoring.\nEquipment requirements\nProcessing requirements\n\n\nR
 eferences\n\n \n\nFor more information visit https://medtechiq.ning.c
 om/events/implement-parametric-release-in-eo-sterilization-a-practical
DTSTART;TZID=America/New_York:20120911T100000
DTEND;TZID=America/New_York:20120911T110000
CATEGORIES:medical, device, compliance
LOCATION:Online Event
WEBSITE:http://www.complianceonline.com/ecommerce/control/trainingFocu
 s/~product_id=701452?channel=MedtechIQ
URL:http://www.complianceonline.com/ecommerce/control/trainingFocus/~p
 roduct_id=701452?channel=MedtechIQ
CONTACT:+1-650-620-3915
ORGANIZER;CN=Referral:https://medtechiq.ning.com/profile/Referral
ATTACH;FMTTYPE="image/jpeg":http://storage.ning.com/topology/rest/1.0/
 file/get/2562006613?profile=original
ATTENDEE;ROLE=REQ-PARTICIPANT;PARTSTAT=ACCEPTED;RSVP=TRUE;CN=Referral:
 https://medtechiq.ning.com/profile/Referral
END:VEVENT